Arriving · Floor 8
Code & Resource Department
The Hoistway Line
8

Floor 8 · Department landing

Code & Resource Department

Member landing · Safety First leads every job. Browse this desk, then ride the car to the next floor.

Floor 8

Code & Resource Department

ASME, local amendments, and the paperwork that makes a job legal. Reach here before you argue with an inspector.

Quote the section, the edition, and the local amendment. 'I think code requires…' is how meetings go sideways.
Category tests, load tests, and acceptance checklists. Know what the AHJ expects on paper before you schedule the truck.
Some work needs a permit; some needs a conversation. This desk helps you tell which is which in your jurisdiction.
OEM manuals, wire charts, and solid references — not random forum screenshots. Bookmark the shelf you trust.
Passenger elevators, home elevators, platform lifts and dumbwaiters do not all follow the same rules. Start by naming the equipment correctly, then confirm the adopted code and local amendments. Please verify with your inspector.
Acceptance and periodic tests show that brakes, safeties, doors and emergency features do their job under stated conditions. Only trained, authorized people perform them, using the maker instructions and the governing test code. Please verify.
Escalators rely on devices that stop the unit for step, handrail, skirt and landing problems. Knowing what each device watches helps staff report trouble clearly, but testing and resetting belong to qualified personnel. Please verify.
Home elevators and chairlifts follow rules written for homes and limited use, which differ from public passenger elevators. Permits, inspections and who may service them vary by place. Please verify locally before work starts.
Limited-use elevators, wheelchair lifts and dumbwaiters look similar to a casual eye but carry different people, loads and rules. Misnaming the unit leads to the wrong parts and the wrong inspection. Please verify its classification.
Hydraulic safety depends on pressure being limited and the car being supported if a line fails. The exact devices and test steps belong in the maker manual and adopted code for that unit. Please verify before any test.
Records should name the same unit that sits in the shaft, not a sister car across the hall. When a report arrives, check the unit identity, date and findings, then forward it promptly and file it where the next person can find it.
Codes are revised and adopted differently by city and state. If a section, test interval or permit step is unsure, mark it please verify and ask the inspector or authority having jurisdiction rather than guessing.
Controls, signals, door timing and clear floor space decide whether a rider can use a unit independently. Local accessibility rules and elevator rules work together. Please verify both for alterations.
Keep the adopted code, test records, maker instructions for your units, and inspector contacts together, with dates. A shelf no one updates becomes history, not a resource, so review it after every inspection or alteration.
A binder of visits should show a plot: faults found, what changed, and whether the same complaint returns. Read for repeats and unanswered items, and raise them at the next visit instead of filing paper you never open.
Elevator testing runs on recurring cycles, with some items checked more often and deeper proof tests on a longer cycle, witnessed and recorded as local rules require. Your inspector sets the schedule for your unit. Please verify.
Good test days are prepared: access open, records ready, building staff informed, and a mechanic who can explain each step. Riders get clear signs and alternate routes, because a test is planned work, not a surprise outage.
Capacity plates, inspection tags and machine-space labels connect the paper record to one physical car. If a plate is missing or unreadable, report it; guessing capacity or identity is never acceptable. Please verify.
Stage lifts, orchestra lifts, sidewalk elevators and similar equipment carry duties written for their special work. Do not borrow passenger-elevator habits or schedules without confirming their own rules. Please verify.
Start with what the equipment is, then the adopted edition and local amendments, then the maker instructions for that unit. An internet answer for another city or year can be confidently wrong. Please verify.
Changing fixtures, controls, machines or entrances can trigger design review, permits and acceptance work beyond the swap itself. Treat the first quote conversation as a compliance conversation too. Please verify.
Inspectors expect a space that is accessible, lit, dry and holding only elevator-related items, with records available. A monthly five-minute look by building staff keeps inspection day from becoming a scramble.
Safety First: know the family before you need it. Depending on age and model, protection can include stop switches at both landings, comb impact devices, skirt switches, handrail inlet switches, broken step-chain and broken drive-chain devices, missing-step detection, handrail speed monitoring, braking-distance monitoring, and reversal or overspeed protection on newer units. Each one is tested on the maintenance control program schedule — tested, never bypassed. Exact device lists vary by unit, please verify on site. Safety First — This is the Way.
Safety First: testing proves a device works; inspection judges the unit against the code your jurisdiction enforces. Escalators get periodic tests of their safety devices and brake performance on the program schedule, and periodic inspections by authorized inspectors using the inspectors guide alongside the requirements code. Keep the written results with the unit records — a passed test nobody recorded helps no one at the next visit. Editions and intervals vary, please verify with your authority having jurisdiction. Safety First — This is the Way.
Safety First: the safest rider aids are the ones nobody has to think about. Caution signs at both landings, clear safety zones kept free of kiosks and displays, deck barricades that stop climbing, infill panels between adjacent units, good step-band lighting, demarcation markings that show where each step ends, and guards where ceilings intersect the balustrade — check them like machinery, because a missing guard is a finding, not decor. Safety First — This is the Way.
Safety First: lifts for people with disabilities are often used by riders who cannot step away from a problem. Platform lifts and stairway chairlifts follow their own safety standard (A18.1), not the elevator code. It is split into commercial and residential vertical lifts, incline lifts, and stairway chairlifts, plus driving means, engineering tests, and inspections. Shop synopsis of the 2003 edition: commercial lifts inspected at least every 6 months, private-residence lifts at least every 12 months — please verify for your jurisdiction and edition. Safety First — This is the Way.
Safety First: from a synopsis of the 2003 edition (please verify against the edition in force): capacity 450–750 lb; platform up to 18 sq ft; speed up to 30 fpm; travel up to 5 ft unenclosed or 12 ft otherwise; headroom at least 80 in; full passenger enclosure on the platform not allowed; capacity, data, and 'no freight' tags required. Safeties required except on direct-plunger hydraulic; normal and final limits required; up/down controls must be held (constant pressure); a positive-opening emergency stop; and a means to operate from outside the platform. If the rider cannot be seen, an alarm or two-way communication is needed, with standby power. Safety First — This is the Way.
Safety First: incline lifts run along stairs used for exit — never block the way out. Synopsis points (2003 edition, please verify): at least 3/4 in running clearance; platform edge no more than 24 in above the stairs; capacity 450–750 lb; slope up to 45°; speed up to 30 fpm; platform up to 12 sq ft with a safety pan; machine brake except on direct-plunger hydraulic or self-locking drives. Guarding is either a full enclosure with a self-closing locked gate and grab rail, or restraining arms with locks, contacts and an emergency unlock, plus ramps or guards on the boarding sides; only the ramp at the current landing may move. Safety First — This is the Way.
Safety First: home lifts often run unattended in places where children and pets play — treat locks and guards as must-work items. Synopsis points (2003 edition, please verify): residential vertical lifts need a self-closing upper gate near the sill, smooth fascia, a monitored retractable guard or ramp at the lower landing, locks with electric contacts on every gate, a safety pan, 450–750 lb capacity, travel up to 12 ft, speed up to 30 fpm. Residential incline lifts need at least 20 in clear passage, 6 in guards, and ramps that rise automatically with an electric contact; a seat is allowed. Emergency signals are not required on residential units but are recommended. Safety First — This is the Way.
Safety First: when a lift's driving means fails, the platform must stop safely — test those devices. Synopsis points (please verify): roped-hydraulic lifts use at least two ropes; slack rope switches should need manual reset; every hydraulic cylinder needs a stop ring; there are rules for flexible hose and fittings and for manual operation; and engineering tests cover safety nuts on screw drives and speed governors. Safety First — This is the Way.
Safety First: you cannot test right if you test to the wrong book. Florida assigns each elevator a state serial number, and the code edition that applied when it was permitted is the one it was built to. From the state's 2024 effective-date table: A17.1-2019 effective 12/31/2023; A17.1-2016 effective 12/31/2020; A17.1-2013 effective 12/31/2017. The existing-equipment code A17.3 (2020 edition effective 12/31/2023) applies retroactively to all elevators and escalators. Platform lifts and chairlifts: A18.1-2020 effective 12/31/2023, 2017 effective 12/31/2020. Electrical: NEC 2017 effective 12/31/2020. Check the current table before each job — please verify. Safety First — This is the Way.
Safety First: tests with weights, governor trips, and safeties are among the highest-risk work we do — plan them, brief everyone, and keep the public out. Under the newer editions, traction periodic tests are grouped as Category 1 (annual, no load in the car: things like governor tripping, safety and limit functions, buffer checks) and Category 5 (every five years, often with rated load: car and counterweight safeties, governor tripping speed and pull-through, buffer tests, braking with overload). Older editions used different item numbers for the same ideas. The inspectors' guide lists, for each item, the periodic inspection, the periodic test, the acceptance check, and the code references — please verify which items and intervals apply to your car's edition. Safety First — This is the Way.
Safety First: never load a car past what the test calls for, and keep everyone off the car top during load tests. Shop points from the inspectors' guide: the driving-machine brake must hold the car with 125% of rated load; traction is checked by loading the car and confirming the ropes do not slip or, where the test calls for it, that they do slip when the counterweight bottoms; governor rope readings are taken and recorded; and brake settings are examined against the data tag. Exact steps and percentages by edition — please verify. Safety First — This is the Way.
Safety First: inspect with the unit barricaded and under your control. The inspectors' guide splits escalator work into what you see from the outside (steps and step width, skirt panels and skirt clearance, combs, handrails, balustrades, caution signs, entrance and egress areas, and a skirt performance index on some editions) and what you see inside the truss (main drive chain and sprockets, driving-machine brake, broken drive-chain and step-chain devices, inspection control and its stop switches, and more). Each item has its own periodic, test, and acceptance entry with references — please verify by edition. Safety First — This is the Way.
Safety First: ride tests are done with the car on normal service and the crew clear of the hoistway. Ride quality used to be 'feels good to me.' Today it can be measured with a standard (ISO 18738) that defines the terms — peak-to-peak vibration, speed, acceleration, and jerk — the instrument, how to place it, and how to analyze the data. The standard does not set a pass/fail number; the spec or contract does. Measure before and after a mod or adjustment so you can show the change. Safety First — This is the Way.
Safety First: never mix rope types or reuse damaged rope. A separate standard (A17.6) covers suspension, compensation, and governor ropes and their newer cousins such as belts. It is where the rules for rope construction, fastenings, and replacement criteria live. Use it with the elevator code, not instead of it — please verify the edition referenced by your code. Safety First — This is the Way.
Safety First: when the code is unclear on a safety item, ask before you act. The code committee publishes official interpretations that answer specific questions. They explain what the committee meant for that edition; they do not change the code. Look up an interpretation by edition and requirement, and keep a copy with the job if you relied on it. Safety First — This is the Way.
Safety First: weight tests are the most dangerous tests we run — never ride a car loaded past rated load. A static brake test loads the car, typically to 125% of rated load, and checks that the brake holds the car without sliding. A dynamic brake test checks that the brake can stop the moving car within limits. Where there is a main brake and a secondary brake, each is tested by itself with the other held off. Before the test, confirm the counterweight balance from the original layout: balanced load = overbalance percentage × rated load (for example 40% × 3000 lb = 1200 lb). If the sheave moves with the balanced load and the brake lifted, the balance is wrong — stop and call your supervisor. Please verify percentages by code edition. Safety First — This is the Way.
Safety First: plan access to both the car top and the car interior before you trip the governor. In a no-load safety test, the car is run down slowly, the governor is tripped to set the safeties, and the machine runs until the ropes slip or the drive stalls. Afterward the car must have stopped close to level: one shop rule is no more than 3/8 inch per foot of distance between guides, about 1.8 degrees, checked with an angle gauge on the crosshead — please verify the requirement for your edition. For drum-type safeties, the pull-out of the safety rope before the jaws grip has maximum limits by car speed. Safety First — This is the Way.
Safety First: governor tests involve a running car and an open governor — keep hands away from the rope and sheave. Five-year governor work includes checking that the governor trips at the right speed and that, once tripped, the governor rope pulls the safety out with enough force (pull-through). Do preliminary maintenance first: clean, lube and inspect the governor, rope and tension sheave. Different governor styles (flyball, newer designs) have different test and adjustment methods — follow the maker. Seal and tag the governor after adjustment. Safety First — This is the Way.
Safety First: terminal tests run the car toward the end of the hoistway on purpose — clear the landings and the car top. The normal terminal stopping device slows and stops the car at the ends; the emergency terminal stopping device steps in if the car comes in too fast. Tests are run at the top and bottom landings with normal slowdown defeated in the way the controller allows. Annual checks also include normal and final limit switches and confirming oil buffers return to full extension. Category and method depend on the controller — please verify. Safety First — This is the Way.
Safety First: these devices catch a car moving away from a floor with doors open, or a car running up too fast — test them with nobody near the doors. Newer traction elevators have detection for unintended car movement and ascending car overspeed, acting on an emergency brake (rope brake or sheave brake). Tests are done yearly and in heavier form every five years, using the controller's test mode. Record which device stopped the car and the slide distance. Please verify the category and interval for the unit's code edition. Safety First — This is the Way.
Safety First: this test lets the machine keep turning after the car or counterweight stops — keep clear of ropes and sheaves. A traction-loss test checks that the controller notices when the sheave keeps turning but the car does not (for example, counterweight resting on its buffer) and shuts the machine down. Methods differ for older and newer code editions and by controller. Please verify. Safety First — This is the Way.
Safety First: never put your body under a car or counterweight to look at a buffer. Yearly oil buffer work: check the oil level, look for leaks and corrosion, compress the buffer and confirm it returns fully, and confirm the buffer switch works and stops the car. Some counterweight buffers have two switches — one a rope-monitor and one in the safety string. Know which is which before testing. Safety First — This is the Way.
Safety First: barricade, lock out, test and verify before each powered step. A yearly escalator test plan covers: machine-space stop switches; the drive machine and brakes including brake torque; the speed governor or overspeed device; non-reversal protection; broken drive-chain and step-chain devices; handrail entry and speed monitoring; skirt and step-sag devices; inspection control and its stop; and stopping distance. Record results on the unit's tags and in the MCP. Please verify items by code edition. Safety First — This is the Way.
Safety First: always follow the actual manual for the equipment in front of you. Many manufacturer procedures are confidential and are not reproduced on this site. What you find here are the ideas and lessons in our own words — never a substitute for the maker's step-by-step on the job. Safety First — This is the Way.
Safety First: the exam starts with safety for a reason. Practice tests for Florida's elevator certificate of competency are organized in sections such as safety, hydraulic, traction, electrical and code. Sample safety questions stress reporting every injury to your supervisor right away, removing jewelry and securing loose clothing before work, and wearing work gloves when cleaning pits, car tops and machine rooms. Study the current code edition the state uses — please verify the current exam format with the state. Safety First — This is the Way.
Safety First: wrong data on a report can lead to the wrong test or the wrong part. State unit data reports for hydraulic, roped and wheelchair or chair lifts ask for location, maker, code edition, capacity, speed, rise, openings, door lock types and force readings, clearances (car top, pit depth, runby), buffer data, test dates, plunger and hose data (hydraulic) or rope data (roped), switch checks and lighting. Measure, don't copy last year's numbers. Safety First — This is the Way.
Safety First: lift riders often can't help themselves in a stop — check every guard and lock. Data reports for wheelchair and chair lifts cover vertical and inclined units: location, maker, code, capacity, speed, rise, landings, door or gate types and locks, and the inspection results. Keep a current one with each lift. Safety First — This is the Way.
Safety First: acceptance and yearly testing use deliberate bypasses — log every one and remove them all. Modern controller test procedures group checks into families: door interlocks and gate switch (including in bypass), stop switches, the safety string and contactor and brake feedback, emergency brake (unintended movement and ascending overspeed), inspection speed limits, terminal stopping devices and final limits, buffers, safeties and governor, redundancy of power removal, ground faults, and firefighter and emergency power operation. Which tests and how often depends on code edition — please verify. Safety First — This is the Way.
Safety First: brake tests are done with the car empty or loaded as the test calls for, the hoistway clear and everyone off the car. Measuring how far the car slides when the brake sets lets you compare against the maker's or the code's limits and track brake wear over time. Record the speed, load and distance each time. Limits depend on code edition — please verify. Safety First — This is the Way.
Safety First: governor tests involve overspeed and catching the car — only qualified people, with everyone off the car. The governor's electrical switch must open first, before the mechanical jaws grip the rope. Both trip speeds are set by the rated car speed and must fall inside the code range. Seal the governor after adjustment and record the values. Exact ranges depend on code edition — please verify. Safety First — This is the Way.
Safety First: dumbwaiters have their own code part with many elevator rules modified or removed, but door locks, car door contacts, terminal stopping devices, brakes and stop switches still apply. Power dumbwaiters run on automatic or continuous-pressure operation, and belt drives have speed limits. Machine sheaves have a minimum size relative to rope size. Check your code edition and state — please verify. Safety First — This is the Way.
Safety First: the elevator code points to the electrical and fire alarm codes for wiring. The fire alarm sends separate signals for main floor recall, alternate floor recall, and machine room or hoistway detectors (to flash the fire hat). Shunt trip, where required, cuts power before sprinkler discharge and has its own monitoring. Details vary by edition and local authority — please verify. Safety First — This is the Way.
Safety First: some places require the inspector to witness the governor test after a governor or rope is replaced. Check your code and jurisdiction before scheduling the work, so the car is not left waiting. Record trip speeds and rope data. Please verify. Safety First — This is the Way.
Safety First: coated belts are not inspected like wire rope. The code and maker define the inspection method, interval, and replacement criteria (often with an electronic tester). Know your code edition's rules — please verify. Safety First — This is the Way.
Safety First: overspeed tests drive the car above contract speed — empty car, no one on the car or in the pit, and follow the test procedure exactly. The governor switch and jaws must trip within their code range, and the safeties must stop the car. Values depend on code edition and rated speed — please verify. Safety First — This is the Way.
Safety First: inspect with the unit locked out when reaching into the hoistway. Typical items: hoistway doors and locks, car door contact, terminal limits, ropes or chains, brake, car load sign, machine and controller, stop switch, and pit condition. Confirm local rules for permits and inspections — please verify. Safety First — This is the Way.
Safety First: never test beyond what the procedure calls for. Passenger elevators must safely lower, stop and hold the car with extra load beyond rated capacity (older codes used 125% of rated load) without needing full rated performance. Check your edition — please verify. Safety First — This is the Way.
Safety First: safeties are tested by qualified people only. Some car safeties are clamping types that start slowing almost immediately after the governor trips, with constant clamping force regardless of speed, and reset by lifting the car. Inspect running clearances to the rail and the safety switch, and test per your code. Safety First — This is the Way.
Safety First: test emergency lowering with the car empty and building warned. Older controllers may have emergency lowering relays (lowering one car at a time to a set landing on emergency power) and peak programs. Confirm what your code edition requires for emergency power and lowering — please verify. Safety First — This is the Way.
Safety First: tests by qualified people only. Spring buffers are for lower speeds; oil buffers for higher. Oil buffers must return to full extension after compression within a set time and hold correct oil. Check your code edition for test requirements — please verify. Safety First — This is the Way.
The model code is the baseline. Cities and states amend it. Always check the adopted edition and local bulletins for the building’s address.
Stay calm, show the section, ask what would satisfy the write-up, and escalate through your company if the interpretation still blocks safe completion.
No. They are trade orientation. Final calls belong to your licensed personnel and the AHJ on that job.

Field notes

Procedures, checklists and jobsite notes for this desk — start with the topics above, then search this floor in the lobby ride.

See topics above

Diagrams & refs

Maker callouts and reference sheets for this desk. Keep unit records with the car they name.

See topics above

Shop talk

Field lessons in our own words. Names and places are changed in stories.

See topics above

Resources

Code citations and downloads for this department. Mark anything unsure: please verify.

See topics above